Services and Technical Capabilities

Complete Cylinder Requalification Support

LPG Cylinder Requalification

Requalification support for LPG cylinders including inspection, testing, refurbishment review and certification records.

Outcome: safer cylinder lifecycle management.

CNG Cylinder Requalification

CNG cylinder requalification Nigeria services for steel and composite cylinders across applicable standards.

Outcome: reliable readiness for continued service.

Internal and External Visual Inspection

Inspection for corrosion, dents, gouges, bulging, heat damage, valve condition and internal contamination.

Outcome: visible defects identified early.

Hydrostatic Pressure and Stretch Testing

Cylinder hydrostatic testing with expansion measurement under controlled pressure conditions.

Outcome: strength and permanent expansion assessed.

Ultrasonic Thickness Testing

Wall thickness measurement to evaluate metal loss, corrosion trends and service suitability.

Outcome: data-led inspection decisions.

Ultrasonic Flaw Detection

NDT inspection for relevant discontinuities and internal flaws that may affect cylinder integrity.

Outcome: improved defect detection.

Valve Inspection and Replacement

Valve removal, inspection, replacement and controlled refitting where required.

Outcome: safer valve performance.

Cylinder Cleaning and Controlled Drying

Internal cleaning and drying after testing to reduce moisture and contamination risk.

Outcome: cylinders prepared for safe return.

Cylinder Painting and Refurbishment

Blasting, painting, marking and cylinder refurbishment Lagos services for external condition restoration.

Outcome: improved protection and identification.

Leak Detection Testing

Leak testing after inspection and valve work to confirm containment readiness.

Outcome: leakage risks identified before dispatch.

Internal Borescope Inspection

Visual access to internal surfaces where direct inspection is limited.

Outcome: better understanding of internal condition.

Certification and Re-testing Marking

Documentation, marking and records for cylinder inspection and certification after accepted tests.

Outcome: traceable requalification status.

Facility Systems and Equipment

Degassing and purging facility
Valve removal and refitting station
Cylinder weight verification system
Hydrostatic test system
Ultrasonic flaw detector
Borescope internal inspection
Hardness testing equipment
Controlled drying system
Blasting and painting system
Leak detection equipment

LPG and CNG Coverage

LPG capability table
Cylinder TypeSteel and composite LPG cylinders
Cylinder Sizes3kg, 5kg, 6.5kg, 12.5kg, 25kg and 50kg
Testing ServicesHydrostatic testing, ultrasonic thickness testing and visual inspection
Applicable StandardsNIS 69, NIS 532, NCP 08 and NCP 058
CNG capability table
Cylinder StandardsISO 11439, ISO 9809 and ISO 11120
Cylinder Capacity30 litres to 3000 litres
Cylinder TypeSteel and composite cylinders
Inspection ServicesHydrostatic testing, ultrasonic thickness testing and NDT inspection

Professional Cylinder Processing Steps

Kizuna Energy cylinder testing and requalification process flow chart
Process flow chart from cylinder receiving through inspection, testing, drying, valve fitting, marking and certificate dispatch.
Receiving of cylinder
Recording cylinder identification
External visual inspection
Degassing
Leak testing
Hydrostatic stretch testing
Ultrasonic flaw detection
Ultrasonic thickness testing
Internal cleaning
Internal borescope inspection
Cylinder weight check
Internal drying
Valve inspection and fitting
External painting
Re-testing marking
Dispatch with certificate